Pulmonary Hypertension: Sequencing Panel

Condition Description

Pulmonary hypertension (PH) is increased pulmonary pressure in the absence of common causes such as lung, heart, or thromboembolic chronic diseases. It is thought that both genetic and environmental factors that alter vascular structure and function contribute to the pathogenesis of PH.    

Familial cases of PH are usually inherited in an autosomal dominant manner. With the identification of pathogenic variants in genes known to cause PH, what was previously thought to be idiopathic PH is now known to be genetic. A pathogenic variant in the BMPR2 gene causes ~70% of hereditary cases of pulmonary arterial hypertension (PAH) and in 10-40% of idiopathic PAH. Other genes with pathogenic variants implicated in PH include: CAV1, GDF2, RASA1, SMAD4, and SMAD9.  

Heterozygous pathogenic variants in the ENG and ACVRL1 (previously known as ALK1) genes cause hereditary hemorrhagic telangiectasia (HHT). HHT is an autosomal dominant vascular disorder characterized by acquired cutaneous telangiectasias and arteriovenous malformations that can lead to the development of PAH.  

References:
  • OMIM
  • Ma and Chung. (2014). Hum Genet. [Epub ahead of print]

Genes (8)

Your search may have returned a result for a gene alias. Click here for a full list of genes and their aliases.

Indications

This test is indicated for:
  • Confirmation of a clinical diagnosis of pulmonary hypertension.
  • Carrier testing in adults with a family history of pulmonary hypertension.

Methodology

Next Generation Sequencing: In-solution hybridization of all coding exons is performed on the patient\'s genomic DNA. Although some deep intronic regions may also be analyzed, this assay is not meant to interrogate most promoter regions, deep intronic regions, or other regulatory elements, and does not detect single or multi-exon deletions or duplications. Direct sequencing of the captured regions is performed using next generation sequencing. The patient\'s gene sequences are then compared to a standard reference sequence. Potentially causative variants and areas of low coverage are Sanger-sequenced. Sequence variations are classified as pathogenic, likely pathogenic, benign, likely benign, or variants of unknown significance. Variants of unknown significance may require further studies of the patient and/or family members.

Detection

Next Generation Sequencing: Clinical Sensitivity: A pathogenic variant in the BMPR2 gene can be identified in ~70% of hereditary cases of pulmonary arterial hypertension and in 10-40% of idiopathic PAH.  The clinical sensitivity for ENG, ACVRL1, and CAV1 is unknown. Pathogenic variants in the promoter region, some pathogenic variants in the introns and other regulatory element pathogenic variants cannot be detected by this analysis. Large deletions will not be detected by this analysis. Results of molecular analysis should be interpreted in the context of the patient\'s clinical and/or biochemical phenotype.

Analytical Sensitivity: ~99%.

Specimen Requirements

When sample fails to meet the acceptable criteria, please call 470.378.2200 and ask to speak with a laboratory genetic counselor (eglgc@egl-eurofins.com).
Submit only 1 of the following specimen types
Whole Blood (EDTA)
WBP

Requirements
EDTA (Purple Top)
Infants and Young Children (<2 years of age): 2-3 ml
Children > 2 years of age to 10 years old: 3-5 ml
Older Children & Adults: 5-10 ml
Autopsy: 2-3 ml unclotted cord or cardiac blood
Collection and Shipping
Ship sample at room temperature for receipt at EGL within 24 hours of collection. Do not refrigerate or freeze.
Saliva
SLV

Requirements
Oragene™ Saliva Collection Kit
Orangene™ Saliva Collection Kit used according to manufacturer instructions. Please contact EGL for a Saliva Collection Kit for patients that cannot provide a blood sample.
Collection and Shipping
Please do not refrigerate or freeze saliva sample. Please store and ship at room temperature.
DNA, Isolated
DNA

Requirements
Microtainer
15µg
Isolation using the Perkin Elmer™Chemagen™ Chemagen™ Automated Extraction method or Qiagen™ Puregene kit for DNA extraction is recommended.
Collection and Shipping
Refrigerate until time of shipment in 100 ng/µL in TE buffer. Ship sample at room temperature with overnight delivery.
  • Comprehensive cardiomyopathy panel
  • Pulmonary Hypertension: Deletion/Duplication Panel

How to Order